INSTALLATION TESTER FOR PROTECTIVE CIRCUITRY ACCORDING TO DIN VDE0100, RCD TYPEB

The inclusion of a facility for wide-range measurement makes it possible to use this test meter for all AC and three-phase mains networks with voltages from 65 up to 500 V and frequencies from 15.4 to 420 Hz.

  • 1 Tester
  • 1 Earth contact plug unit (PRO-Schuko)
  • 1 2-pin measurement adapter
  • 1 Lead for enhancement to 3-pin adapter (PRO-A3-II)
  • 2 Crocodile clips
  • 1 Carry belt
  • 1 Set of batteries (8 x LR6)
  • 1 Brief instruction manual
  • 1 Full instruction manual (on CD-ROM)
  • 1 DKD calibration certificate
  • 1 PC program (ETC) for communicating with the tester.
  • Manufactured by Metrawatt: Profitest MTECH
  • Measurement of loop and mains impedance
  • Measurement of insulation resistance at nominal voltage, with variable or increasing test voltage for low-current measurements
  • Measurement of earth resistance
  • Measurement of in-situ insulation
  • Universal connection system
  • Display of authorised fuse/protection components for electrical installations
  • Start test for energy consumption meters
  • Calculation of line length for commonplace cross-sections of copper conductors
  • Measurement of advance, leakage and compensating current up to 1 A as well as operating currents
  • Measurement of direction of rotating field (phase sequence, maximum line voltage)
  • Measurement of contact voltages with no tripping of switches.
    (The contact voltage is measured relative to the nominal residual current and at 1/3 its value.)
  • Trip tests at nominal residual current/ measurement of tripping time

 

Special testing of installations or RCD circuit breakers

  • Testing of installations and RCD circuit breakers via increasing residual current with display of tripping current and contact voltage at the moment of tripping.
  • Testing of RCD circuit breakers at the following currents: ½ × IΔN, 1× IΔN, 2× IΔN, 5× IΔN
  • Testing of RCD circuit breakers suitable for pulsating direct current. Testing can be done on positive or negative half-waves
  • Testing of RCD circuit breakers with adjustable residual current to determine contact voltages and tripping current
  • Testing of tripping by AC or DC with RCDs (type B) which respond to all current types

Evaluation software

  • The software acquires all the key data for logging in accordance with DIN VDE 0100 Part 600
  • Test logs (ZVEH-format) can be generated automatically
  • Distribution structures including circuit and RCD data can be defined individually
  • Structures defined in this way can be stored and loaded into the tester when needed
  • Tester and PC can exchange data in either direction via a USB link
  • Data can be exported in EXCEL, CSV and XML formats