CE 380.01 Flow injection analysis

The flow injection analysis (FIA) supplements CE 380. It uses the photometer in CE 380 as a detector to detect the reaction product glucose.

The multi-channel pump permanently conveys three liquid flows into the FIA. The dissolved reaction products from CE 380 and an indicator reagent are first mixed in one chamber. The mixture then flows through a helical reaction loop. The conduction of the flow in the reaction loop enables an even distribution of all substances. Another indicator reagent is added in a second mixing chamber. After flowing through another reaction loop, the mixture enters the flow cell. There the light intensity is continuously measured with the photometer to determine the glucose concentration. To trigger the discolouration for the photometric measurement, a defined amount of the enzyme glucose oxidase (GOD) is injected through an injection valve. The indicator reagents and the enzyme GOD are not included in the scope of delivery.

CE 380.01 enables more measurements during the experiment than a manual analysis. In addition, the reproducibility is improved and it is no longer necessary to mix each individual sample.

  • professional analyser for CE 380
  • continuous photometric determination of the glucose concentration

Flow cell travel length: 1cm
Multi-channel peristaltic pump

  • 4 channels
  • max. flow rate per channel: 11mL/min at 100min-1 and hose Di=1,42mm

Injection valve

  • 6 connections
  • 2 switch positions

Loops

  • reaction loops: 1x 2000mm, 1x 4000mm
  • injection loop: 1x 100mm

Tanks

  • indicator reagents: 2x 250mL
  • GOD: 1x 25mL
  • waste: 1x 1000mL
  • injection syringe: 1x 10mL

 

230V, 50Hz, 1 phase
230V, 60Hz, 1 phase
120V, 60Hz, 1 phase
UL/CSA optional

  1. continuous, photometric determination of the glucose concentration in the product from CE 380
  2. PTFE flow cell for determining the concentration with the photometer from CE 380
  3. multi-channel peristaltic pump for conveying the product from CE 380and the indicator reagents
  4. injection valve, injection syringe and injection loop for adding the enzyme GOD required for verification
  5. 2 mixing chambers for mixing the product and indicator reagents
  6. PTFE reaction loops
  7. DURAN glass beakers for indicator reagents and GOD
  8. 1 tank for waste
  • using the flow injection analysis (FIA)
  • determining the concentration
  • determining the yield for CE 380