ET 611 Air conditioning system with chamber
Comfort is of great importance in the air conditioning of rooms and buildings. The comfort depends on the temperature, the relative humidity and the flow velocity of the air. According to DIN 13779 a so-called “comfort zone” has been defined which specifies the values an air conditioning system should achieve.
ET 611 is a full air conditioning system with comprehensive test options. The effect of the air humidity and temperature on the comfort is examined. The system has a climatic chamber designed for test persons to be inside. This allows the trainee to study the effect of different system operating states on his own well-being. The components used, such as radial fan, electric air heater, steam humidifier and water chiller are all used in commercial air conditioning and ventilation technology. A PLC air conditioning controller monitors and controls all functions. In addition to the automatic operation it also enables the manual operation of the system.
- real air conditioning system with water chiller and climatic chamber
- chamber for comfort investigations, suitable for test persons to be inside
- air conditioning controller with integrated PLC
- data acquisition by software
PLC air conditioning controller
- 17 universal inputs, 4 analogue outputs, 10 switching outputs
Radial fan
- power consumption: 0,75kW
- max. flow rate: 39m3/min
- pressure difference: 450Pa
Air heater: 6x 250W each
Steam humidifier
- steam capacity: 6kg/h
- power consumption: 4,5kW
Water chiller
- power consumption: 2,1kW
- refrigeration capacity: 6,2kW at 32°C, ΔT=5K
- fan, volumetric air flow rate: 3500m3/h
- compressor, power consumption: 2kW
- pump, power consumption: 550W
Air cooler, capacity: 4,84kW
Measuring ranges
- flow rate: 0…1500L/h
- temperature: 8x 0…50°C
- humidity: 6x 0…100%
- flow velocity: 2x 0…20m/s (air)
- power: 4x 0…6kW
400V, 50Hz, 3 phases
400V, 60Hz, 3 phases
- air conditioning system with chamber for conditioning and air technology investigations
- chamber suitable for test persons to be inside
- PLC air conditioning controller, manual and automatic operation
- industrial components: fans, air-cooled water chiller, air cooler, air heater, steam humidifier
- digital displays for air temperature, air humidity, air velocity, temperature of the cold water, power
- refrigerant R407C, CFC-free
- GUNT software for data acquisition via USB under Windows 7, 8.1, 10
- design, operation and operating behaviour of a real air conditioning system
- recirculating and outer air operation
- changes of state in the h-x diagram for humid air: heating, cooling, humidifying or dehumidifying, mixing
- application of the mixing line
- comfort studies, limit of comfortable humidity
- energy balance in the Sankey diagram
- PLC air conditioning controller
- humidity control
- temperature control
- manual or automatic operation