HL 353.01 Comparison of different heating types

A complete domestic heating system can be set up using the trainer HL 353.01 together with a hot water generator, e.g. HL 353. Hot water passes through the radiators and heats the room air.

HL 353.01 contains two heating circuits. Both circuits are equipped with commercially available heating technology control devices. Each heating circuit contains a circulating pump. A digital, temperature led (outside temperature) heating controller controls the heating circuit (A) with floor heating. A three-way mixing valve is the actuator. The second heating circuit (B) contains a forced convector with temperature controller, a radiator with thermostatic valve and a radiator with one-pipe radiator valve.

The trainer is supplied with hot water from the supply unit HL 353 and is connected to the feed and return flow connectors using hoses with quick-release couplings.

Measuring points for temperature, pressure, differential pressure and flow rate enable energy calculations and evaluations.

  • setup of a complete domestic heating system together with hot water generator HL 353
  • 2 independent heating circuits:
    • floor heating
    • forced convector with fan, 2 radiators
  • control devices for both heating circuits

Floor heating, Cu pipes

  • length: 7500mm
  • diameter pipe: 14mm
  • wall thickness: 0,8mm
  • filling volume: 1,2L/m

Radiator, steel

  • heating capacity: 492W at feed flow 70°C, return flow 55°C and ambient temperature 20°C

Air heater

  • heating capacity: 7,14…9,32kW at feed flow 90°C, return flow 70°C and inlet temperature 15°C
  • max. flow rate: 1260m3/h

Pump

  • max. power consumption: 60W
  • max. flow rate: 3600L/h
  • max. head: 4m

Thermostatic valve: 5…26°C

Measuring ranges

  • pressure: 2x 0…1,6bar
  • differential pressure: 1x 0…0,25bar
  • flow rate: 1x 15…160L/h, 1x 100…1000L/h, 1x 20…250L/h

 

230V, 50Hz, 1 phase

  1. together with hot water generator: setup of a complete domestic heating system with 2 independent heating circuits
  2. heating circuit (A) with floor heating, circulating pump, heating controller, and 3-way mixing valve
  3. heating circuit (B) with forced convector with fan, 2 radiators and circulating pump
  4. 1 radiator with thermostatic valve and 1 radiator with 1-pipe radiator valve
  5. room temperature controller for fan of forced convector
  6. measurement of flow rate and pressure
  7. 8 measuring points for differential pressure and temperature (temperature measurement via sensors of HL 353)
  8. hot water connections with quick-release couplings
  • design of a floor heating with controller and actuator
    • temperature-led heating controller (outside temperature) with three-way mixing valve
  • design of a room heating system with radiators
    • thermostatic valve
    • one-pipe radiator valve
  • design of a room heating system with forced convector with temperature controller
  • function and design of commercially available heating technology components
  • measurement of differential pressures, temperatures and flow rates
  • energy calculation and evaluation of emitted heating capacity
  • reading and comprehension of symbols and process schematics

Web offer

add product
Request for Quotation

Product number

HL 353.01