HL 356 Demo unit, gas burner

The HL 356 demonstrates the basic functioning of an original gas burner and its typical behaviour in case of faults. Standard industrial components are used. All operating states of the burner are simulated, allowing this demo unit to be operated without gas and flames. The unit is therefore totally non-hazardous and has no gas or waste gas lines. On the front panel is a graphical representation of the controller unit connection. Important electrical monitoring points (controller unit terminals) on the burner are accessible for fault analysis using lab jacks and bridges on the front panel. Faults can thus be checked either during operation under voltage or with no voltage as an isolated component.

  • electronic simulation of the operation of a forced air gas burner
  • PLC controlled simulation of nine faults on individual components

Fully automatic air forced gas burner for natural gas

  • power: 15…45kW
  • connection load: approx. 160W
  • motor power: 70W

PLC

  • 16 digital inputs
  • 14 digital outputs
  • 2 analogue inputs
  • 1 analogue output

Digital multimeter

  • for direct or alternating current

230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase
UL/CSA optional

Dimensions and weight

LxWxH: 1330x790x1360mm
Weight: approx. 105kg

  1. simulation model of a forced air gas burner and all burner operating states
  2. fault simulation: 9 fault buttons in lockable box
  3. additional actual system components: flame safeguard, gas pressure and air pressure control devices, ignition transformer, thermostat, safety temperature limiter, gas solenoid valves, fan motor, emergency switch heating system
  4. important electrical monitoring points on burner accessible via lab jacks and measuring bridge connectors for fault analysis
  • specification of boiler temperature at the thermostat (reference variable) using potentiometer
  • specification of boiler water temperature using potentiometer
  • representation of flame aspect and burner operating state displays
  • possible faults (activated using pushbuttons):
    • air pressure control device
    • boiler temperature controller
    • flame safeguard
    • gas solenoid valve
    • fan motor
    • gas pressure control device
    • safety temperature limiter
    • ignition transformer
    • current supply control unit

Web offer

add product
Request for Quotation

Product number

HL 356

HL-356-Demo-unit-gas-burner-gunt-441-pdf_1_en-GB

Download view

HL-356-Demo-unit-gas-burner-gunt-441-pdf_1_en-GB

Download view