HL 860 Exhaust gas analyser

Power can be supplied either using a rechargeable battery, or from the mains. The unit enables, amongst other aspects, the O2, CO, CO2 and nitrogen oxides in flue gases from domestic heating boilers to be measured at the same time as the flue gas and combustion air temperature are measured.

Along with the display, the portable unit is equipped with a thermal printer and a USB interface. A PC can be connected to the USB interface.

  • measurement of all flue gas relevant parameters
  • thermal printer and PC interface integrated

Measuring ranges

  • O2: 0…20,9%
  • CO: 0…2000ppm
  • CO2: depends on fuel
  • NOx: 0…500ppm
  • excess air number: 1,00…9,99
  • flue gas loss: 0…99%
  • combustion efficiency: 0…99%
  • ideal draught: ±60hPa
  • temperature:
    • -20…1000°C (exhaust gas)
    • -20…120°C (combustion air)

 

230V, 50Hz, 1 phase
230V, 60Hz, 1 phase
120V, 60Hz, 1 phase

  1. portable flue gas analyser in metal case, for heating systems
  2. simultaneous measurement of combustion air and flue gas temperature, residual oxygen, carbon monoxide, flue gas loss, combustion efficiency, ideal draught and excess air number
  3. rechargeable battery operation or mains operation possible
  4. USB interface
  • measurement of residual oxygen in the flue gas of heating systems
  • measurement of carbon monoxide, carbon dioxide
  • measurement of nitrogen oxide
  • measurement of flue gas and combustion air temperature, other measurements

Web offer

add product
Request for Quotation

Product number

HL 860