HM 215 Two-stage axial fan

Axial fans are connected in series in plants to increase the pressure. In theory, connecting two fans in series doubles the pressure increase.

The HM 215 trainer allows the investigation of a two-stage axial fan. A measuring device is used to determine the pressure and velocity distribution.

The trainer includes a measuring section with two identical axial fans. The carefully designed nozzle contour and a flow straightener at the air inlet ensure a uniform velocity distribution with little turbulence in the measuring section. The rotors are equipped with individually adjustable blades to change the angle of attack. The fans are equipped with outlet guide vane systems. These guide mechanisms redirect the angular momentum of the outflow in the axial direction and allow an increase in pressure. A pipe bend may optionally be installed to rotate the flow at the outlet of the measuring section. One of the fans can be removed from the measuring section so that the remaining fan can be studied in individual operation.

In the measuring section there are measuring connections to detect the differential pressures and temperatures. The flow rate is measured via an inlet nozzle. The differential pressure and the angle of attack are detected radially at rotors and guide vane systems by means of the 3-hole probe. This enables the display of different pressure and velocity profiles. The measured values are read from digital displays and can at the same time be transmitted via USB directly to a PC where they can be analysed using the software included.

  • two axial fans in series configuration or in individual operation
  • three-hole probe for determining pressure and velocity profile

2 fans

  • drive motor rated output: 3,45kW
  • max. pressure difference: 798Pa
  • speed: 0…2850min-1
  • blade angle adjustable up to 39°

Measuring section inner diameter: 400mm

Measuring ranges

  • temperature: 0…100°C
  • differential pressure: ±25mbar
  • radial position of the probe: 100…200mm

 

400V, 50Hz, 3 phases
400V, 60Hz, 3 phases

  1. investigate two-stage axial fan
  2. 2 identical single-stage fans in series configuration or individual operation
  3. individually adjustable blades
  4. fans both with variable speed via frequency converter
  5. flow-optimised nozzle and flow straightener for smooth, low-turbulence flow
  6. air flow in the pipe section can be adjusted via throttle valve
  7. optional pipe bend at the outlet for flow deflection
  8. measuring device with three-hole probe for determining the differential pressure on rotor and guide vane system
  9. sensors for pressure and temperature upstream and downstream of each fan
  10. volumetric flow rate measured via inlet nozzle
  11. GUNT software for data acquisition via USB under Windows 7, 8.1, 10
  • determining the fan characteristic
  • series configuration or individual operation of axial fans
  • determining the energy balance
  • determining the radial pressure and velocity distribution on rotor and guide vane system by means of a probe
  • effect of the blade position

Web offer

add product
Request for Quotation

Product number

HM 215