SE 130.01 Truss beam: Warren girder

Warren truss beams are frequently used on steel constructions.

Experiments with the truss SE 130.01 are mounted on the frame of the SE 130 unit. The mechanical construction of the truss ensures that only tensile or compressive forces are active in the bars. The connection between the bars by means of node disks is “hinged”. So this can be described as an ideal truss.
The force in the bars is measured using strain gauge measurement. Owing to the symmetrical construction, only half of the bars have measuring points on them. All strain gauge connections are housed together in the strain gauge box.

  • ready assembled Warren truss
  • bars with strain gauge measurement to measure bar force

Truss beam: Warren type

  • bar cross-section: 10x3mm, stainless steel
  • bar lengths: 270mm, 186,5mm
  • tensile force: max. 500N
  • bars: 13, of which 7 with measuring points

Node disks: 8

  1. investigation of bar forces in a single plane, statically determinate truss
  2. ready assembled Warren truss beam
  3. influence of dead-weight minimised by horizontal experiment layout
  4. any straight and inclined load cases possible
  5. pre-balanced strain gauge connection box
  6. SE 130.01 is a supplementary set for the main unit SE 130
  • calculation of tensile and compressive forces in bars in different load cases: straight and inclined forces
  • comparison of measuring results with mathematical methods
    • method of joints
    • Ritter’s method of sections
    • Cremona diagram

Web offer

add product
Request for Quotation

Product number

SE 130.01