HL 358 Forced air gas burner training panel
The trainer contains a commercially available forced air gas burner. The elements for a gas controlled system are combined into one compact fitting.
The burner function is simulated using air making it possible to use the unit in training rooms without hazard. The compressed air is supplied by a small integrated compressor.
- practical nominal load adjustment
- display of the most important operating pressures
- burner control sequence
- hazard-free due to operation with air
Gas burner
- rating class: 15…45kW
Gas pressure controller
- admission pressure: 0,4bar
- outlet pressure: 0,04bar
Diaphragm pump
- power consumption: 70W
- max. flow rate: 70L/min at 230mbar
Measuring ranges
- flow rate: 0,5…5,5Nm3/h (air)
- pressure: 3x 0…50mbar
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase
UL/CSA optional
- simulation of the operation of a gas burner
- hazard-free operation of the burner with air
- diaphragm pump for pressure generation, pumping medium: air
- display of the most important operating pressures on single tube manometers
- indication of burner operation using a flickering light
- monitoring of burner operation using flame safeguard
- EXCEL-file for calculating the operating volume included in the delivery
- familiarisation with components for heating systems
- starting a gas burner
- nominal load adjustment on a gas burner
- fault-finding and fixing
- calculation of the gas flow rate / operating volume