HL 500 Instantaneous gas heater

The housing and heat exchanger of the instantaneous heater have been removed to clearly show the internal components. For safety reasons, the trainer is operated with air. Burner flames are simulated using an array of LEDs.

A diaphragm pump with pressure regulator generates the compressed air required for operation at the correct admission pressure. All the necessary safety functions such as lighting the pilot, thermocouple flame safeguard and temperature cut-out are simulated electronically using a PLC.

The PLC is programmed to simulate a total of twelve different faults.

  • methods of gas burner adjustment
  • simulation of twelve faults

Instantaneous heater

  • nominal thermal output: 19,2kW

Diaphragm pump

  • max. flow rate: 70L/min

Gas pressure controller: 16…28mbar

Measuring ranges

  • pressure:
    • 0…6bar (water)
    • 0…60mbar (gas)
  • differential pressure: 10-0-10mbar
  • flow rate:
    • 0,75…7Nm3/h (gas)
    • 75…1000L/h (water)

 

230V, 50Hz, 1 phase
120V, 60Hz, 1 phase
230V, 60Hz, 1 phase
UL/CSA optional

  1. simulation of an instantaneous gas heater
  2. safe operation of heater using air
  3. diaphragm pump for pressure generation
  4. PLC simulation of safety functions
  5. simulation of 12 faults by PLC
  • gas burner adjustment by volumetric method
  • nozzle pressure method for gas burner adjustment
  • fault finding

Web offer

add product
Request for Quotation

Product number

HL 500